INSTALLATION
5-23
System 2 Installation / Programming Manual
Transformer and Battery
Transformer
The main power source for System 2 is a UL listed transformer. Primary 120V, 60hz, .48A / Secondary
16.5VAC, 40 VA. If the 16.5VAC output terminals are shorted, the internal fuse will open and the
transformer will be useless. It should be noted that the fuse is impossible to repair. Attempting to repair it is
dangerous and also voids the UL Listing! The transformer measures 2.75" x 2.625" x 3.875" (69.8 mm x 66.6
mm x 98.4 mm). It may not be used to power any other devices, other than the System 2. Refer to Figure 8.
CAUTION: This transformer has an internal fuse which cannot be repaired or replaced.
External Standby Battery
If AC power is lost, the System will operate normally by automatically switching to the standby lead-acid
battery. The System charges this battery at a voltage of 13.8 volts. Operating time under battery standby
conditions will vary depending upon system activity and the type of Card Readers or Keypads used.
Typical battery operation times are listed below and assume normal system activity and usage. These are only
estimates, other factors that will effect battery operation time depend on battery condition, number of LEDS ,
type of readers, programmed relay time etc.
4 amp/hr battery 6 amp/hr battery
1 or 2 Data Chip Readers 14 hrs. 20 hrs.
1 or 2 Keypads 14 hrs. 20 hrs.
1 Bar Code Reader 10 hrs. 15 hrs.
2 Bar Code Readers 08 hrs. 12 hrs.
1 Mag-Stripe reader 12 hrs. 19 hrs.
2 Mag-Stripe Readers 11 hrs. 18 hrs.
1 Proximity Reader 08 hrs. 13 hrs.
2 Proximity Readers 06 hrs. 10 hrs.
1 Wiegand Reader 13 hrs. 20 hrs.
2 Wiegand Readers 12 hrs. 18 hrs.
To install the battery, locate the supplied wire harness. It consists of a nylon plug attached to a pair of six inch
red and black wires, each with a .187 inch spade terminal for connection to the battery. Observe polarity and
connect the RED to Positive (+) and the BLACK to Negative (-). Plug the nylon plug into socket H1 located
in the lower left hand corner of the circuit board. The battery may be connected after the AC power is
connected. Allow 24 hours for the battery to reach full charge. Refer to Figure 8.