PC/VDT PROGRAMMING - AUXILIARY OUTPUTS
9-191
System 2 Installation / Programming Manual
Note: Although the display states the Option is Not Active, the output(s) have been assigned to the
selected schedule. However, it will not activate until the Second Door has been turned ON. Proceed to
Option #13 to turn this Option ON.
The unit assigns this output to the schedule for those customers who wish to upgrade a one-door system
(2003) to a two-door system (2016) in the future, but do not wish to re-program the outputs.
Automatic Output Operation
This is the point at which you may assign a schedule to the output... provided you have
installed a two-door System 2 (2016). The VDT will display the instructions:
Use 0 thru 6
0=No Schedule
Port Schedule [_0]
Note: If you have a two-door System 2 (2016), the amount schedules available is 16.
At the Port Schedule [ _ 0 ] prompt, enter your selection followed by ENTER.
The output will activate as configured (momentary or latching) at the start and end time of a
time schedule.
If you wish this output to be inactive 24 hours a day, seven days of the week (unless
programmed to trigger from any of the available events) either press 0 and ENTER or just
ENTER. No schedule will be assigned to this output.
If you selected any of these Outputs to trigger from a schedule and you have not activated the
Second Door the VDT will display:
Option Not Active
Install in Option 13
Press Any Key
After you are finished programming the Schedule section, the VDT will display the instructions:
Enter Aux Output
1=Aux Relay 1
2=Aux Relay 2
3=Voltage Output 1
4=Voltage Output 2
Output [1]
At the Output [ 1 ] prompt, enter your next selection followed by ENTER.
If you are finished press 0.
If you are operating the System 2 in network mode, and you assign a trigger event to a output,
that function operates locally to each unit in the network. This means that if you, for example,
assign Aux Relay #1 to trigger on a door ajar, Aux Relay #1 on the master will trigger if the
door ajar occurs on the master; Aux Relay #1 on Slave #1 will trigger if the door ajar occurs on
Slave #1, etc. This, of course, holds true for any other system event.