PC/VDT PROGRAMMING - ADD/CHANGE KEYPAD CODES
9-196
System 2 Installation / Programming Manual
Note: Although the display states the Option is Not Active, the output(s) have been assigned to the selected schedule.
However, it will not activate until the Second Door has been turned ON. Proceed to Option #13 to turn this Option ON.
The unit assigns this output to the user codes for those customers who wish to upgrade a one-door system (2003) to a two-
door system (2016) in the future, but do not wish to re-program the outputs.
If you attempt to enter a code which is already used, you will see the following prompt:
Press Any Key
Duplicate Code!
Additional Outputs
When a valid code is entered, the door relay for that Port will, by default, be activated. In
addition to this activation of the door relay, you might want other outputs to be activated as well
to, for example, sound an alarm, trip a dialer, or send some other signal. There are four such
outputs from which to choose. The Program Aux Outputs section of this manual details the
physical properties of the outputs. Any, all, or none of these outputs may be activated by a user,
if the Second Door has been activated.
Refer to Option #13 to purchase this option.
The VDT will display the instructions:
Assign These Output(s)
To User ID
1=Aux Relay 1
2=Aux Relay 2
3=Voltage Output 1
4=Voltage Output 2
0=None
Outputs [----]
At the Outputs [----] prompt, enter the desired output(s), if any, then press ENTER.
Example: If you are programming the code 12345 and select Outputs 1 and 3, each time the
code 12345 is used the door will open and Aux Relay 1 and Voltage Output 1 will trigger...
provided you have installed a two-door System 2 (2016).
If you are operating the System 2 in its networking mode, outputs triggered by a valid user
operate locally to each unit. In other words, if our valid user who is programmed to trigger
outputs 1 and 3 enters at a door on the master, the master’s outputs 1 and 3 will be triggered. If
this same user enters at a door on Slave #1, outputs 1 and 3 on Slave #1 will be triggered -- and
so on for all other units on the network.
If you select any of these Outputs and you have not activated the Second Door the VDT will
display:
Install in Option 13
Option Not Active
Press Any Key