LCD PROGRAMMING - ADD/CHANGE KEYPAD CODES
8-97
System 2 Installation / Programming Manual
1=Yes, 2=No
Enter Anti-Passback [ 2 ]
0=Make User Permanent þþþþ
Enter Temporary Type [ 0 ]
Users Enrolled 0001 þþþþ
Want to Continue? [ 1 ]
Anti-Passback
(You may not be permitted to program Anti-Passback). This is a Premium Option. To activate
Anti-Passback, Door 2 must be installed. Refer to Option #13.
Anti-Passback is a powerful, but perhaps a little confusing, security tool. Before you program
a user for Anti-Passback, refer to Option #7, where this is discussed in detail. The LCD will
scroll:
At the Enter Anti-Passback [ 2 ] prompt, pick the desired type then press # (enter).
User Type
(You may not be permitted to program User Type).
This is a Premium Option which is packaged with the second door.
To purchase Door 2, refer to Option #13.
A user can be programmed as permanent, to expire after a programmed date, or to expire after
a programmed number of uses - provided you have purchased this option from Corby.
The LCD will scroll the instructions:
Scrolling Options: 1=Expire On a Date
2=Expire After # Times
Enter your selection and press #.
After you have successfully entered a user, the current System status will be displayed.
Scrolling Options: Users Remaining 0412
1=Yes, 2=No
If you wish to program another user press 1. If you are finished programming users, press 2.