Vacation Hold
In Vacation Hold mode, the thermostat ignores program schedule and remote system temperature setting changes for the duration
of your scheduled time away. Vacation Hold can only be initiated at the Omnistat2 thermostat.
When an Omnistat2 thermostat is in Vacation Hold, the temperature display on the console or touchscreen for the selected
Omnistat2 thermostat will display Vacationin the place it would normally display the status of Hold. You can not initiate a
Vacation Hold command from the controller, but you are able to switch from Vacation Hold to Hold On or Hold Off.
Humidity Display
If your Omnistat2 is equipped with a humidity sensor, from a console or touchscreen, you can view the current relative humidity.
Humidity Setpoints
Humidity Setpoints are used to control connected equipment used for humidification and dehumidification.
The Humidify setting is used to control a stand alone humidifier.
The Dehumidify setting is used to control: a) the Fan Speed of an HVAC system with a variable speed fan, used to augment the
dehumidification process, or b) a stand alone dehumidifier.
These humidify and dehumidify settings can be modified from a console, touchscreen, or automation program. The humidify
setting may be adjusted at a console by selecting 6 (HMFY) from the temperature menu of the selected Omnistat2 thermostat:
Upstairs HUMIDIFY
ENTER HUMIDITY:
Enter the desired humidity level, and then press ' # ' to save setting. If the humidity level falls below this setting, the output
connected to the humidifier (if applicable) is activated.
The dehumidify setting may be adjusted at a console by selecting the 7 (DFHY) from the temperature menu of the selected
Omnistat2 thermostat:
Upstairs DEHUMIDIFY
ENTER HUMIDITY:
Enter the desired humidity level, and then press ' # ' to save setting. If the humidity rises above this setting, the output connected
to the HVAC fan control or dehumidifier (if applicable) is activated.
Outdoor Temperature
If your Omnistat2 is equipped with an external outdoor temperature sensor, you can view the outdoor temperature from a console
or touchscreen. The outdoor temperature can also be used as a condition in an automation program.
Occupancy Status
When the Program Mode of your Omnistat2 is configured for Occupancy”, the program setpoints are based on the occupancy
status of OmniPro II controller. Whenever the security mode changes on the OmniPro II, it will send the current occupancy mode
(Day, Night, Away, or Vacation) to Omnistat2 thermostat. When configured in the manner, you can easily adjust the heat and
cool settings for each occupancy mode on the Omnistat2 without ever having to create or edit automation programs stored in the
controller.
Time and Date
The OmniPro II now sends the current time of day and the date to the Omnistat2. As long as the time and date is correct on the
OmniPro II, there is no need to set the time or date on the Omnistat2.