C-Bus group address 0 is not supported. C-Bus lighting groups can be turned on, turned off, brightened, dimmed, set to a specific
level, or toggled on/off. OmniPro II supports two-way integration with the Clipsal C-Bus lighting system. Individual lighting
groups can be directly controlled and lighting scenes can be triggered by the LEVITON controller. OmniPro II monitors C-Bus
lighting and can respond to changes.
Controlling Clipsal C-Bus from an Omni Console
Use the Control menu to control lighting loads and Clipsal C-Bus devices. To enter the Control menu, from the top-level display
or from the main menu, press the 1 (CTRL) key on the console keypad.
OmniPro II will automatically display the first named unit.
To control a lighting load or Clipsal C-Bus device, select it from the list of units, and then press the ' # ' key.
Press 0 (OFF) to turn the selected lighting load off
Press 1 (ON) to turn the selected lighting load on
Press 2 (DIM) to dim the selected unit (1-9 steps, each step is 10% from its current level)
Press 3 (BRT) to brighten the selected unit (1-9 steps, each step is 10% from its current level)
Press 4 (LVL) to set the desired lighting level of the selected unit (0%-100%)
5 (RMP) is not used with Clipsal C-Bus
Press 9 (TIM) to time the selected unit (On, Off, Dim, Brighten)
Timed commands may be from 1-99 seconds, 1-99 minutes or 1-18 hours
Press # (STA) to see the status of the device.
Note: When a Clipsal C-Bus signal is received over the network, OmniPro II will automatically update the status of the device.
Programming for Clipsal C-Bus Units
Note: To take advantage of the controlling Clipsal C-Bus s devices via OmniPro II programming, programs must be written using
the LEVITON PC Access Software, Version 3.2 or later.
OmniPro II can be programmed to execute commands when a unit is turned on or off.
Likewise, OmniPro II can be programmed to control Clipsal C-Bus switches and dimmers (on, off, toggle, dim, brighten, setting
to a specific level) and to control scenes.
OmniPro II also allows C-Bus lighting scenes to be activated through the use of C-Bus triggers”. A C-Bus trigger command
contains a Trigger/Scene Group and a Trigger/Scene Action. The combination of Trigger Group and Trigger Action is used to
create scenes that may be considered mutually exclusive or scenes that are unrelated. Scenes that share the same Trigger Group
number are considered mutually exclusive. Scenes that do not share the same Trigger Group number are considered unrelated.
The Trigger Action is used to indicate what set of actions should be taken when the scene is triggered.
Mutually exclusive scenes may be used when it is desired that activating one of the scenes will cancel indicators for the other
scenes. For example, there may be buttons on a keypad to select different lighting scenes in a room, such as OFF, ON, READ,
and WATCH TV. Pressing one of the buttons will illuminate the indicator on the button and turn off the indicators on the other
three buttons. These scenes share the same Trigger Group, but have different Trigger Actions to specify the desired scene.
LEVITON PC Access software may be used to create a Clipsal C-Bus scene command. This command includes the C-Bus
Trigger/Scene Group (1-254) and Trigger/Scene Action (1-32). This command may then be included as part of a programming
sequence or can be assigned to an LEVITON “button” for activation through an LEVITON user interface.