Myalarm V-LED1 Manual do Proprietário Página 1

Consulte online ou descarregue Manual do Proprietário para Sistemas de segurança - controlo de acesso Myalarm V-LED1. Myalarm V-LED1 Owner`s manual Manual do Utilizador

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 124
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 0
Control & Security System
Owner’s Manual
Includes the SIA CP-01 Control Panel Standard
Features for False Alarm Reduction
WEB VERSION
Vista de página 0
1 2 3 4 5 6 ... 123 124

Resumo do Conteúdo

Página 1 - WEB VERSION

Control & Security SystemOwner’s ManualIncludes the SIA CP-01 Control Panel Standard Features for False Alarm ReductionWEB VERSION

Página 2

Page 1 INTRODUCTION Thank you for purchasing your new OmniPro II automation system. You are about to enjoy a new feeling of security, comfort, con

Página 3

Page 91 CANADIAN INDUSTRY CANADA NOTICE Notice: The Industry Canada label identifies certified equipment. This certification means t

Página 4

Page 92 APPENDIX A - DIAL OUT PLANNER Use the following dial-out planner to help you set-up the voice dial-out numbers: OmniPro II Voice Dial-O

Página 5

Page 93 INSTRUCTIONS TO CALLED PARTY Dear ___________________________________________________________________ I have programmed my OmniPro II Hom

Página 6

Page 94 APPENDIX B - TEXT DESCRIPTION CHARACTER CODES CODE CHAR CODE CHAR CODE CHAR CODE CHAR 00 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15

Página 7

Page 95 APPENDIX C - VOICE DESCRIPTION CODES CODE DESCRIPTION 255 (ADDRESS MSG) 58 (BEEP) 254 (MEMO MESSAGE) 29 (PAUSE) 30 (SHORT PAUSE) 26 A. M.

Página 8

Page 96 CODE DESCRIPTION 341 FALL 80 FAMILY 81 FAN 342 FATHER’S 343 FAULT 344 FEBRUARY 217 FENCE 5 FIFTEEN 17 FIFTY 218 FILE 345 FILTER 82 FIRE 219

Página 9

Page 97 CODE DESCRIPTION 444 ONLINE 445 ONLY 233 OPEN 446 OPTION 131 OR 447 OTHER 448 OUT 132 OUTDOOR 133 OUTLET 449 OUTSIDE 450 OVER 234 OVERFLOW

Página 10

Page 98 CODE DESCRIPTION 250 VAULT 536 VCR 537 VIDEO 538 VISITOR 539 VOLUME 540 WAITING 541 WALK 542 WALKWAY 251 WAREHOUSE 543 WARNING 187 WATER 54

Página 11

Page 99 APPENDIX D – FIRMWARE UPDATES Description The OmniPro II Version 3.2 firmware adds the following new features: • Support for Clipsal C-B

Página 12

C-Bus group address 0 is not supported. C-Bus lighting groups can be turned on, turned off, brightened, dimmed, set to a specific level, or toggled

Página 13

Page 2 OVERALL DESCRIPTION Console Operation The console is designed with everything that is necessary for you to program and operate your OmniPro

Página 14

About Lutron HomeWorks Lutron RadioRA uses a network of low voltage wires to communicate with and control HomeWorks lighting device

Página 15

Programming for Lutron HomeWorks Units Note: To take advantage of the controlling HomeWorks devices via OmniPro II programming, programs must be w

Página 16

User Settings User Settings consist of numbers, levels, times, dates, days of the week, durations, temperature settings, and humidity settings that

Página 17

Program Blocks In previous version of the controller firmware, each automation program was constructed of a single line that consi

Página 18

d. Thermostats: current temperature, heat setpoint, cool setpoint, heater currently running, air conditioning currently running, system

Página 19

Vacation Hold In Vacation Hold mode, the thermostat ignores program schedule and remote system temperature setting changes for the duration of your

Página 20

Energy Status When OmniPro II sends the time and date to the Omnistat2, it also sends the current Energy Level. When the Ener

Página 21

LEVITON Access Control LEVITON Access Control allows you to access doors by opening an electric or magnetic lock, arm and disarm

Página 22

Note: When a valid card or key tag is presented at the reader, all 9 LED indicators will illuminate and remain illuminated until the “Door Unlock” t

Página 23

Method A) Typing in the ID Number of the Access Control Card or Key Tag: a. Enter the last 8 digits of the Access Control Card or Key Tag and the

Página 24

Page 3 6- UP ARROW The Up Arrow key is used to scroll through menus and lists. The Up Arrow is used to scroll back through a list (for example, if

Página 25

Each Access Control Card or Key Tag can be assigned to 1 or more Access Control Readers. When an Access Control Card or Key Tag is assigned to spec

Página 26

WEB VERSION

Página 27

WEB VERSION

Página 28

WEB VERSION

Página 29

LEVITON LIMITED WARRANTYLeviton warrants to the original consumer purchaser and not for the benefit of anyone else that products manuf

Página 30

Page 4 When using the arrow keys to scroll through lists of areas, buttons, codes, temperature zones, units, or zones, only the name

Página 31

Page 5 To silence “Trouble Beeps”, press the ' * ' key. For more information, see Trouble Indications. Confirmation Beep When you have s

Página 32

Page 6 SECURITY SYSTEM OPERATION Disarming the Security System and Silencing Alarms Before going any further, you should know how to disarm your

Página 33

Page 7 2 = NIGHT The NIGHT mode is used when you are asleep and everyone in your household is at home. In the Night mode, you

Página 34

Page 8 What Happens When You Arm the Security System To arm the system into one of the 6 security modes, from the security menu, choose the security

Página 35

Page 9 Bypassing Zones 8 = BYPASS You can Bypass a zone that you do not want protected while the system is armed. Bypassing is also the only way t

Página 36

Page 10 What To Do When You Come Home If you enter your home while the system is armed in the Day, Night Delay, Away, or Vacation mode using an entr

Página 37

WEB VERSION

Página 38

Page 11 Fire Alarm Activated When the fire alarm is activated by the smoke/fire detector(s), the alarm responds exactly as described

Página 39

Page 12 Police Emergency When the 1 key and the 3 key is pressed simultaneously, the Police Emergency alarm is activated. This alarm operates exact

Página 40

Page 13 Trouble Indications The OmniPro II constantly monitors the alarm zones and several internal matters and will alert you if i

Página 41

Page 14 Manager Code The Manager codes can arm/disarm the security system in assigned areas, during assigned times. The Manager code can access fun

Página 42

Page 15 If the ' 0 ' (ALL) key had been selected, the display will show: DISARM ALL AREAS ENTER CODE: #=AREA As the fou

Página 43

Page 16 Testing Your System LEVITON recommends testing your system on a weekly basis to ensure that you are fully protected. 1. Notify your Cent

Página 44

Page 17 CONTROL Control Commands The control features of the OmniPro II make it easy and convenient to control almost any light or appliance from t

Página 45

Page 18 When set to UPB, the OmniPro II controller can:  Send commands (on, off, bright, dim and level) to individual switches and modules  Rece

Página 46

Page 19 When “Status Tracking” is enabled (this is the default setting), OmniPro II keeps track of the exact status of each unit even when a lighting

Página 47

Page 20 The first unit number in each room (i.e. 1, 9, 17, 25, etc.) is reserved for controlling the room. The name for this unit should ref

Página 48

WARNINGS AND CAUTIONS• Read and understand all instructions. Follow all warnings and instructions marked on the product.• Do

Página 49

Page 21 About ALC ALC is intended for installation in homes, which have been pre-wired for installation of ALC system products. O

Página 50

Page 22 Unit Numbers OmniPro II systems have 511 total Unit Numbers. They consist of HLC, UPB, Z-Wave, CentraLite, RadioRA, ALC, Compose, and X-10

Página 51

Page 23 Scrolling Through Names The OmniPro II stores names for Units, Zones, Buttons, Codes, Temperatures, and Messages so that you don't hav

Página 52

Page 24 Each lighting scene can also be set or easily changed using the pushbuttons on the LEVITON UPB™ 6-Button Room Controller, as follows: Step Op

Página 53

Page 25  Press 0 (OFF) to turn the selected room off (all lighting loads in the room are turned off).  Press 1 (ON) to turn the selected room on

Página 54

Page 26 Controlling RadioRA Units Entry Lights 0=OFF 1=ON 2=DIM 3=BRT ↓ Entry Lights 4=LVL 5=RMP 9=TIM #=STA↑  Press 0 (OFF) to turn the

Página 55

Page 27 Ramp Command (ALC) When ALC Switch Modules are being used, it is possible to ramp the lighting level of an ALC Dimmer Switch to a new level

Página 56

Page 28 Timed Commands The timed commands allow a units to be turned on or off for a specified period of time. The unit may be turned On fo

Página 57

Page 29 Controlling Outputs The OmniPro II has eight outputs that can be used to switch relays. Outputs 1-8 are controlled as Unit Numbers 385-392,

Página 58

Page 30 Leviton Scene Control OmniPro II supports Leviton Scene Control (a feature found in certain Leviton Switches). There are 256 Scenes that ca

Página 59

Contents INTRODUCTION ...

Página 60

Page 31 Scene Off Command Once the Scenes have been sent, press the 0 (OFF) key to command the four units in that Scene to turn off. Notes: 1. W

Página 61

Page 32 Executing Phantom Buttons OmniPro II can turn on and turn off each of the 17 possible Phantom Buttons. Phantom Buttons must be pre-programm

Página 62

Page 33 Buttons A powerful feature of the OmniPro II is the ability to program Buttons. A Button (also known as macro) is a number on

Página 63

Page 34 LEVITON RC-Series Thermostats The following control actions are allowed for LEVITON Communicating Thermostats: • Set heating setpoints •

Página 64

Page 35 The fan control on a thermostat may be switched between on and auto by selecting 4 (FAN) from the temperature menu: Upstairs FAN

Página 65

Page 36 Cool temperature - the air temperature will be allowed to rise to this temperature when the energy saver is on. The following control action

Página 66

Page 37 Downstairs 0=OFF 1=ON 2=HEAT ↓ Downstairs 3=COOL 9=TIME #=STAT ↑ ENTER TIME MINUTES (1-99) #=H

Página 67

Page 38 When a temperature sensor is selected from the list of temperature devices, you may set a “Low” and “High” setpoint for a

Página 68

Page 39 Status The Status function is used to display the status of various items in the system. To enter the status menu, fro

Página 69

Page 40 1=CTRL 2=ZONE 3=SUN ↓ Press 1 (CTRL) to view the current status of each unit and to configure the HLC device that

Página 70

Testing Your System ...

Página 71

Page 41 2 = ZONE The Zone Status menu allows you to view and scroll through the status of each zone input. To enter the Zone menu, from the Stat

Página 72

Page 42 The next series of displays shows the current analog reading for each security zone input. The displays show the readings for zones 1-

Página 73

Page 43 Event Log The Event Log records the 250 most recent significant security system Events (happenings) and trouble conditions in the system. W

Página 74

Page 44 Messages The Message menu is used to play and record the memo message and to quickly clear all text messages. The memo message is an eight-

Página 75

Page 45 Show Message The 1 (SHOW) key allows you to display the selected text message(s) on the console's top-level display. This can be a

Página 76

Page 46 Send Message (Pro-Link) The 6 (SEND) key allows you to send any of the text messages through the Pro-Link serial port. Y

Página 77

Page 47 TELEPHONE CONTROL Telephone Interface Your OmniPro II is equipped with a built-in telephone response feature that allows you to control and

Página 78

Page 48 Phone Access Denied - Remote Lockout The OmniPro II has a remote lockout feature to discourage youngsters (and adults who act that way) fro

Página 79

Page 49 1 - Control Press 1 from the MAIN MENU to get to the CONTROL menu. If voice descriptions have been programmed, after a three-second

Página 80

Page 50 Press the temperature zone you wish to control, then press #. Press the ' 0 ' key to select all LEVITON Thermostats. This is a si

Página 81

Programmable Energy Saver Modules (PESMs) ...

Página 82

Page 51 8 - Message This command allows you to record and verify the voice memo message, allows you to record and play custom mes

Página 83

Page 52 To play one of the custom phrases, press the 6 key. " PLAY PHRASE: ENTER PHRASE NUMBER, THEN POUND." Press the phrase number (1

Página 84

Page 53 Emergency Dial-Out Emergency dial out consists of two distinct parts: the "digital dialer" and the "voice dialer". Dig

Página 85

Page 54 What You Hear - If Your OmniPro II Calls You When you pick up the phone and say something, the OmniPro II will say one of the following, dep

Página 86

Page 55 Built-In Ethernet Port The built-in Ethernet port (J6) allows a device to connect to the OmniPro II controller via a network (i.e. Ethernet,

Página 87

Page 56 192.168.0.101192.168.0.50192.168.0.51HAI OmniPro IIControllerHub orRouterComputerComputer Local Network Dynamic DNS If the controll

Página 88

Page 57 Local / Wide Area Network To connect to an OmniPro II controller on a local network using LEVITON PC Access, under Configur

Página 89

Page 58 SETUP Configuration and Advanced Control Programming (ACP) The Setup menu is used to configure operating parameters, program your

Página 90

Page 59 Access Areas After an authority level has been entered, you will be prompted for access areas for the user. Specify which area(s) (if part

Página 91

Page 60 If Daylight Savings Time is currently being observed (between spring and fall), set this item to "Yes". If Daylight Savings Time i

Página 92

Voice Dialer ...

Página 93

Page 61 1 = Add Programs The 1 (ADD) key is used to add new automation programs to the system. When you press the 1 (ADD) key, the Edit Program men

Página 94

Page 62 The first program is displayed once the down arrow is pressed. The top line displays the time or button/event that activates the program and

Página 95

Page 63 Edit Programs When Selecting the 1 (WHEN) key, from the Edit Program menu, allows the time or button/event that activates t

Página 96

Page 64 Button and Event Programs Selecting 2 (BUTTON), from the "Edit When" menu, sets up a program to be activated when a macro button i

Página 97

Page 65 Corresponding Switch Table Switch OmniPro II UPB 6-Button Keypad UPB 8-Button Keypad RadioRA Master Control ALC 4-Button StarLite Keypad 1

Página 98

Page 66 AREA: ENTER AREA 0=ALL ↓ The area number should be entered followed by the ' # ' key, or the arrow keys may b

Página 99

Page 67 Alarm Event Buttons Pressing the 5 (ALARM) key allows you to specify an event button activated upon the occurrence of an

Página 100

Page 68 The arrow keys are used to select from a list of event buttons: • WHEN ENERGY LO • WHEN ENERGY MID • WHEN ENERGY HI • WHEN ENERGY CRIT

Página 101

Page 69 Edit Program Command Selecting 2 (CMD), from the Edit Program menu, allows the commanded action for the program to be specified. The

Página 102

Page 70 Unit Toggle Command Using LEVITON PC Access Software, you can create programs to toggle any unit (1-511) from its current state to the oppos

Página 103

Edit Program Condition ...

Página 104

Page 71 Program Button Commands Select the 3 (BUTTON) key to program a macro button. Specify the macro button to be executed - See Button Programs

Página 105

Page 72 Program Message Commands Select the 8 (MESSAGE) key to show, log, clear, say, phone, or send a message. Specify the desired command - See M

Página 106

Page 73 Edit Program Condition Selecting the 3 (&COND) key, from the Edit Program menu, allows the condition for the program to be specified. T

Página 107

Page 74 The zone will be displayed and you will be prompted for the state of the zone: IF Front Door: 0=SECURE 1=NOT RDY Program Tim

Página 108

Page 75 Set Up Dial The Set Up Dial menu is used to configure all of the telephone related items for the OmniPro II. To enter the Set Up Dial menu,

Página 109

Page 76 Dial Out Number 1 Dial Out Number 1 is one of the 8 numbers that are stored in the system. In the event of an alarm, these numbers are dial

Página 110

Page 77 Set Up Arming To configure different arming and disarming options, from the Setup menu, press the 5 (ARM) key. Entry Delay The Entry Delay

Página 111

Page 78 Entry/Exit Chime When Entry/Exit Chime is set to Yes, the console(s) will beep once when a door on an entry/exit zone is opened, even if the

Página 112

Page 79 Set up Miscellaneous To configure Miscellaneous items in the system, from the Set Up menu, press the 6 (MISC) key. High Security Mode In H

Página 113

Page 80 House Codes 1-16 Format House Codes 1-16 can be configured to use the Standard (Preset Dim Command), Extended Code (Level Command), Lightoli

Página 114

UNDERWRITER'S LABORATORIES REQUIREMENTS ... 89 FIRE ESCAPE PLANNING ...

Página 115

Page 81 Time Clocks There are three Time Clocks in the system are used to conditionalize programs. They are used solely to define time periods duri

Página 116

Page 82 It is not necessary to alter the time zone to compensate for daylight savings time, the OmniPro II will automatically adjust i

Página 117

Page 83 Controller IP Address The controller’s local network IP address is used to identify the OmniPro II controller on the network. To view and a

Página 118

Page 84 Set Up Names The system can be set up to display descriptive names such as "FRONT DOOR", "JOHN'S BEDROOM", or "

Página 119

Page 85 Set Up Address The final setup item is accomplished over the telephone. This is the address that the system says when it

Página 120

Page 86 AUDIO CONTROL Once configured by your installer, from any OmniTouch touchscreen, you can control on/off, volume, muting, transports, Audio S

Página 121

Page 87 Unit numbers 473-508 are allocated for the Audio Zone names. These names should match the names of each Audio Zone in your audio distributio

Página 122

Page 88 Table 1 - Audio Commands Code LEVITON Hi-Fi Russound 1 NuVo 2 NuVo Grand Concerto Xantech 3 Speakercraft 4 1 Power Power Power Power Powe

Página 123

Page 89 UNDERWRITER'S LABORATORIES REQUIREMENTS For a complete list of requirements and restrictions when installing the OmniPro I

Página 124

Page 90 FEDERAL COMMUNICATION COMMISSION NOTICE: 1. This equipment complies with Part 68 of FCC Rules. On the door, inside of the

Comentários a estes Manuais