Myalarm Genesys 824 Alpha Especificações Página 21

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 22
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 20
3440-0241 Rev G20
The minimum requirements to form a Listed Grade A Local system includes:
Low Battery alarm annunciation (unless dialer is used to transmit a low battery message).
CURRENT RATING CHART
CONTROL (G-824) = 100 mA
KEYPAD (G-KP) = 24 mA
FIRE MODULE (G-FM3) = 50 mA
EXPANSION BOARD (G-EX) = 29 mA
KEYPAD (G-KP ALPHA) = 40 mA
BATTERY CALCULATIONS
EXAMPLE:
4 HOUR STANDBY PLUS 15 MINUTE BELL RINGING:
G-824 Control (with keypad) = 124 mA x 4 hours = .496 AH
Bell = 125 mA x 15 minutes= .031 AH
60
G-824 Control (with keypad) = 124 mA x 15 minutes = .031 AH
60
TOTAL = .558 AH
WORKSHEET:
Control (G-824) 100 mA x _____________ Hours = __________AH
Keypad (G-KP) 24 mA x _______ Hrs x # of Keypads = __________AH
Bell ____mA x 15 minutes = ___________AH
G-FM3 50 mA x _____________ Hours = _ _________AH
Control (while bell ringing) 100 mA x 15 minutes = _____.025__AH
Keypad (G-KP ALPHA) 40 mA x ________ Hrs x # of Keypads = __________AH
Switched Aux. Power _____mA x ______________Hours = ___________AH
Continuous Aux. Power _____mA x ______________Hours = ___________AH
TOTAL = ___________AH
BATTERY SPECIFICATIONS
Yuasa –
Model NP7-12 (12VDC 7.0AH)
Powersonic –
Model PS-1270 (12VDC 7.0AH)
Vista de página 20
1 2 ... 16 17 18 19 20 21 22

Comentários a estes Manuais

Sem comentários